Essential details
Shipping:Ocean freight
Product Introduction
Product name: Cervical spine test evaluation training system
Product model: FAJZ1903
Product specifications: 1360*1060*1900mm(length * width * height)
Weight: 327kg
Product composition: test seat, load mechanism, load driving device, force and motion range sensor, color touch screen display, motion positioning/limiting device, motion safety protection device.
Product model: FAJZ1903
Product specifications: 1360*1060*1900mm(length * width * height)
Weight: 327kg
Product composition: test seat, load mechanism, load driving device, force and motion range sensor, color touch screen display, motion positioning/limiting device, motion safety protection device.
1. Main functions and uses of the equipment:
1-1. Test and evaluate the range of motion and strength of cervical spine flexion, extension and lateral flexion.
1-2. Perform visual biofeedback strength training on the cervical spine.
2, equipment auxiliary function description:
2-1. The rotating center of the monitor rocker arm is located above the human body axis line, and the rotating display can always keep the display screen facing the human body axis, without loosening and adjusting the display joint. The overall monitor rocker arm system is a removable component for easy installation and maintenance.
2-2. Resistance is provided by a synthetic mechanism controlled by a servo motor as the core component.
2-3. The seat and two limit clamp cushion mechanism can be electrically adjusted to the height of the trainer's scientific training by manual switch and display control switch.
2-4. The position of the head cushion can be rotated or moved left and right by loosening the quick screws to achieve the appropriate position for the trainer.
2-5. The seat can be rotated and adjusted in four stations. Lift it up through the duck foot handle below and rotate the chair 90 degrees,180 degrees,270 degrees clockwise. The rotating mechanism is a reciprocating adjusting mechanism and cannot be rotated.
2-6. When the trainer's legs are long, there is a hand wheel to adjust the width of the seat surface until it is satisfied and comfortable.
2-7. The human body sensor detection head is installed in the center of the base of the clamp pad, which is used to open the laser head in the center of the training rotor. When someone is detected sitting on the seat, the laser head opens and sends a Red Cross cursor to remind the rotation center of the human movement and the rotation center of the training mechanism to calibrate, and achieve the best position by lifting the seat and adjusting the limit pad left and right.
2-8. The locking mechanism of the head cushion lever adjustment device adopts stainless steel fast locking mechanism, which provides more convenience for the trainer.
2-9. The clamp pad is composed of double guide rod double linear bearing combined with TR16x4 trapezoidal lead rod and double row angular contact bearing mechanism. The lead rod nut seat is 45 steel integrated processing to increase its rigidity.
2-10. The lifting mechanism of the clamping column pad is composed of 4 box type linear bearings and two 30mm outer diameter high-strength polished rods to achieve the accuracy and safety of the limit adjustment.
2-11. There are three M16 lifting screw holes on the lower side of the vertical frame and the front side of the base, which are easy to transport and fix.
1-1. Test and evaluate the range of motion and strength of cervical spine flexion, extension and lateral flexion.
1-2. Perform visual biofeedback strength training on the cervical spine.
2, equipment auxiliary function description:
2-1. The rotating center of the monitor rocker arm is located above the human body axis line, and the rotating display can always keep the display screen facing the human body axis, without loosening and adjusting the display joint. The overall monitor rocker arm system is a removable component for easy installation and maintenance.
2-2. Resistance is provided by a synthetic mechanism controlled by a servo motor as the core component.
2-3. The seat and two limit clamp cushion mechanism can be electrically adjusted to the height of the trainer's scientific training by manual switch and display control switch.
2-4. The position of the head cushion can be rotated or moved left and right by loosening the quick screws to achieve the appropriate position for the trainer.
2-5. The seat can be rotated and adjusted in four stations. Lift it up through the duck foot handle below and rotate the chair 90 degrees,180 degrees,270 degrees clockwise. The rotating mechanism is a reciprocating adjusting mechanism and cannot be rotated.
2-6. When the trainer's legs are long, there is a hand wheel to adjust the width of the seat surface until it is satisfied and comfortable.
2-7. The human body sensor detection head is installed in the center of the base of the clamp pad, which is used to open the laser head in the center of the training rotor. When someone is detected sitting on the seat, the laser head opens and sends a Red Cross cursor to remind the rotation center of the human movement and the rotation center of the training mechanism to calibrate, and achieve the best position by lifting the seat and adjusting the limit pad left and right.
2-8. The locking mechanism of the head cushion lever adjustment device adopts stainless steel fast locking mechanism, which provides more convenience for the trainer.
2-9. The clamp pad is composed of double guide rod double linear bearing combined with TR16x4 trapezoidal lead rod and double row angular contact bearing mechanism. The lead rod nut seat is 45 steel integrated processing to increase its rigidity.
2-10. The lifting mechanism of the clamping column pad is composed of 4 box type linear bearings and two 30mm outer diameter high-strength polished rods to achieve the accuracy and safety of the limit adjustment.
2-11. There are three M16 lifting screw holes on the lower side of the vertical frame and the front side of the base, which are easy to transport and fix.
Equipment features and technical parameters:
1-1. Can perform the strength test and training of neck forward flexion, back extension and left and right lateral flexion in two movement modes of equal length and equal tension.
1-2. The range of motion of the neck can be tested for forward bending, backward extension and left and right lateral flexion.
1-3. There are two modes of rehabilitation training and strength training.
1-4. Visual biofeedback strength training is possible.
1-5. Equipped with a pressure sensor, it can accurately measure the maximum force of equal length with an accuracy of 0.1KG.
1-6. Equipped with displacement sensor, can accurately measure the range of motion, accuracy of 1 degree.
1-7. Equipped with light wave detector, the system can automatically sense the use of the trainer.
1-8. Equipped with visible laser calibrator, positioning indication before starting use or action conversion, to ensure the safety and accuracy of the test.
1-9. The height and width of the trunk fixed pad can be adjusted without pole, with scale indication.
1-10. The starting Angle of the training rotating arm is 13 degrees (the starting Angle of the resistance pad is 0 degrees), and the pull pin on the disk can be pulled out and rotated to the position that it thinks appropriate,12 degrees first gear.
1-11. Resistance arm position can be adjusted without pole, with scale indication.
1-12. The system can automatically generate strength training curves and periodic training plans according to the evaluation results: according to the curves, the speed, range of activity, frequency, number of groups and interval time can be limited to ensure the safety of personnel testing and training.
1-13. There is a positive spin training curve, which can be set and provided training according to the needs of the tester. The visual biofeedback strength training conducted by tracing the curve provides the effectiveness, safety and science of the training.
1-14. The exercise weight, number and frequency of training groups, interval time, training amplitude and speed in the training plan can be set according to the individual situation of the tester, and the knob setting and press confirmation are convenient to enter the setting.
1-15. Equipped with a 10-inch color touch screen, it is convenient for the tester to view the training curve, display the tester information and training Settings.
1-16. The system has the function of recording and reading test personnel information and training results, which can be recorded and queried in the computer.
1-17. Test and training results of the same tester at different times can be compared and analyzed.
1-18. In the rehabilitation mode, a resistance curve in the flexion and extension cycle can be customized to achieve isotonic power end.
1-19. The size of the load is adjusted linearly through the display screen and knob, the resistance range is 0.5-15KG, the accuracy is 0.1KG.
1-20. Test and train the safety (exhaustion) protection device, pat the emergency stop button on both sides of the seat with the palm of the hand, and the device will immediately stop at the position at the time of movement, and the athlete can leave the training contact point with zero load, so as to avoid possible injury caused by exhaustion.
1-1. Can perform the strength test and training of neck forward flexion, back extension and left and right lateral flexion in two movement modes of equal length and equal tension.
1-2. The range of motion of the neck can be tested for forward bending, backward extension and left and right lateral flexion.
1-3. There are two modes of rehabilitation training and strength training.
1-4. Visual biofeedback strength training is possible.
1-5. Equipped with a pressure sensor, it can accurately measure the maximum force of equal length with an accuracy of 0.1KG.
1-6. Equipped with displacement sensor, can accurately measure the range of motion, accuracy of 1 degree.
1-7. Equipped with light wave detector, the system can automatically sense the use of the trainer.
1-8. Equipped with visible laser calibrator, positioning indication before starting use or action conversion, to ensure the safety and accuracy of the test.
1-9. The height and width of the trunk fixed pad can be adjusted without pole, with scale indication.
1-10. The starting Angle of the training rotating arm is 13 degrees (the starting Angle of the resistance pad is 0 degrees), and the pull pin on the disk can be pulled out and rotated to the position that it thinks appropriate,12 degrees first gear.
1-11. Resistance arm position can be adjusted without pole, with scale indication.
1-12. The system can automatically generate strength training curves and periodic training plans according to the evaluation results: according to the curves, the speed, range of activity, frequency, number of groups and interval time can be limited to ensure the safety of personnel testing and training.
1-13. There is a positive spin training curve, which can be set and provided training according to the needs of the tester. The visual biofeedback strength training conducted by tracing the curve provides the effectiveness, safety and science of the training.
1-14. The exercise weight, number and frequency of training groups, interval time, training amplitude and speed in the training plan can be set according to the individual situation of the tester, and the knob setting and press confirmation are convenient to enter the setting.
1-15. Equipped with a 10-inch color touch screen, it is convenient for the tester to view the training curve, display the tester information and training Settings.
1-16. The system has the function of recording and reading test personnel information and training results, which can be recorded and queried in the computer.
1-17. Test and training results of the same tester at different times can be compared and analyzed.
1-18. In the rehabilitation mode, a resistance curve in the flexion and extension cycle can be customized to achieve isotonic power end.
1-19. The size of the load is adjusted linearly through the display screen and knob, the resistance range is 0.5-15KG, the accuracy is 0.1KG.
1-20. Test and train the safety (exhaustion) protection device, pat the emergency stop button on both sides of the seat with the palm of the hand, and the device will immediately stop at the position at the time of movement, and the athlete can leave the training contact point with zero load, so as to avoid possible injury caused by exhaustion.